Vue de la page 67
Fuel Quality Grade
Use commercially available diesel fuel with less than 0.5% sulfer
content. If the sulfur content is higher than 0.5%, the intervals
between oil changes should be halved e.g. change oil every 250
hours. Don’t use fuel with more than 1% sulfur!
The following fuel specifications / standards are approved:
• CENEN590orDIN/EN590(underdevelopment)
• DIN51601(Feb.1986)
• BS2869(1988):A1andA2
• ASTMD975-88:D1andD2
• NATOCodeF-54andF75
The exhaust emission levels determined during certification by
the supervising authority are always based on the reference fuel
described by law.
Winter-grade fuel
Waxing may occur at low temperatures, clogging the fuel system
and reducing engine efficiency.
If the ambient temperature is less than 0°C (+32°F), winter-grade
fuel -suitable down to -15°C (+5°F) - should be used. This fuel is
usually available from filling stations well in advance of the cold
months. Diesel fuel containing additives (Super Diesel) is often
on sale as well, for use down to -20°C (-4°F).
Fuel
9 Operating media
66
Vue de la page 67